Welcome! Please use the navigational links to explore our website.
PartsASAP LogoCompany Logo (800) 853-2651

Shop Now

   Allis Chalmers Case Farmall IH Ford 8N,9N,2N Ford
   Ferguson John Deere Massey Ferguson Minn. Moline Oliver
 
Marketplace
Classified Ads
Photo Ads
Tractor Parts
Salvage

Community
Discussion Forums
Project Journals
Your Stories
Events Calendar
Hauling Schedule

Galleries
Tractor Photos
Implement Photos
Vintage Photos
Help Identify
Parts & Pieces
Stuck & Troubled
Vintage Ads
Community Album
Photo Ad Archives

Research & Info
Articles
Tractor Registry
Tip of the Day
Safety Cartoons
Tractor Values
Serial Numbers
Tune-Up Guide
Paint Codes
List Prices
Production Nbrs
Tune-Up Specs
Torque Values
3-Point Specs
Glossary

Miscellaneous
Tractor Games
Just For Kids
Virtual Show
Museum Guide
Memorial Page
Feedback Form

Yesterday's Tractors Facebook Page

  
Farmall & IHC Tractors Discussion Board

Re: Super A Charging, needs flash every time I use it


[ Expand ] [ View Replies ] [ Add a Reply ] [ Return to Forum ]

Posted by Janicholson on December 19, 2007 at 19:44:36 from (66.173.50.43):

In Reply to: Super A Charging, needs flash every time I use it posted by scott#2 on December 19, 2007 at 19:05:19:

Not really, I have seen generators go several years W/O loosing polarization. The pull in voltage of the cutout relay in the new VR is probably set too high.
This adjustment is one that requires a bit of understanding of the content of that can. The cutout has the biggest contacts, with heavy solid wire going to them. There is a spring that pulls these apart when the generator is stopped. This prevents the battery from draining into it when its output is less than bat volts. Low idle, or shut off. A very timid (small) incremental (tiny) loosening of the tension. will get it right. If the system reliably opens when taken to an idle, or shut off, it is then fixed. The needle on the amp gauge will slowly go towards discharge when Idled down all the way, (it may get to 3 amps or so discharge) then it will snap a little and go to just a tiny discharge. The same happens when it is shut off, but the needle goes back to 0 . If the needle goes to 10 or more discharge and stays there, it has been loosened too much. Disconnect the Big wire on the generator to prevent it from getting hot and letting smoke out.
A good book (like Motors automotive dictionary) is a great help. Google Voltage regulator cutout adjustment for possible help. Or buy a new VR. I hope this helps, Keep us informed on the results. JimN


Replies:




Add a Reply

:
:
:

:

:

:

:

:

:

: If you check this box, email will be sent to you whenever someone replies to this message. Your email address must be entered above to receive notification. This notification will be cancelled automatically after 2 weeks.


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Today's Featured Article - Uncle Cecil's Super A Lives Again - by Mike Purcell. A week or so out of most of my childhood summers was often spent with my Uncle Cecil and Aunt Sissie in the small East Texas town of Maydelle on their 80 acre farm. Some of my fondest memories of these visits are those of learning to drive a tractor at the helm of Uncle Cecil’s 1948 Farmall Super A. Uncle Cecil was the second owner of this wonderful little tractor, but it was almost as though he had adopted an infant. The original owner was a man from Minnesota who bought her from a local dea ... [Read Article]

Latest Ad: Sell 1958 Hi-Altitude Massey Fergerson tractor, original condition. three point hitch pto engine, Runs well, photos available upon request [More Ads]

Copyright © 1997-2024 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy